PCA9665_2 © NXP B.V. 2006. All rights reserved.
Product data sheet Rev. 02 — 7 December 2006 21 of 91
NXP Semiconductors
PCA9665
Fm+ parallel bus to I
2
C-bus controller
30h Data byte in I2CDAT
has been transmitted;
NACK has been
received
Load data byte or 0 0 0 X 0 Data byte will be transmitted;
ACK/NACK will be received
no I2CDAT action
or
1 0 0 X 0 Repeated START will be transmitted;
no I2CDAT action
or
0 1 0 X 0 STOP condition will be transmitted;
STO flag will be reset
no I2CDAT action 1 1 0 X 0 STOP condition followed by a START
condition will be transmitted;
STO flag will be reset
38h Arbitration lost in
SLA+W or Data bytes
No I2CDAT
action or
00000 I
2
C-bus will be released;
PCA9665 will enter Slave mode.
No I2CDAT
action or
00010 I
2
C-bus will be released;
PCA9665 will enter the Slave mode.
No I2CDAT
action
1 0 0 X 0 A START condition will be
transmitted when the bus becomes
free
Table 27. Master Transmitter Byte mode (MODE = 0)
…continued
Status
code
(I2CSTA)
Status of the
I
2
C-bus and the
PCA9665
Application software response Next action taken by the PCA9665
To/from I2CDAT To I2CCON
STA STO SI AA MODE